0 item(s)

SEMI-CONDUCTOR REFRIGERANT LEAK DETECTOR (W/O PUMP) Item No.MET801R

MET801R
MET801R

SEMI-CONDUCTOR REFRIGERANT LEAK DETECTOR (W/O PUMP)Item No.MET801R

* Dimensions: 7.2" × 2.8" × 1.6" (184 × 70 × 40mm)
* Weight: 10.0 OZ. (280g)

Q'TY/ CTN N.W./KG G.W./KG CUFT PACKAGE
20 18 19 5 PLASTIC BOX

* Sensor: Heated diode
* Refrigerants: R-22, R134a, R404a, R410a, AND ALL CFCs, HCFCs AND HFCs
* Sensitivity levels: High 0.25 OZ./ YEAR (7g/ Year)
* Medium: 0.5 OZ./ YEAR (14g/ Year)
* Low: 0.99 OZ./ YEAR (28g/ Year)
* Reset: Manually reset to bakcground level
* Warm up time: 90 Seconds
* Battery type: 9V Battery
* Audio alarm: Yes (Buzzer)
* Auto power off: 10 Minutes of idle
* Low battery indicator: Yes
* Tip light: Yes
* Flexible probe length: 18" (450mm)
* Operating temp. anD % RH: 32℉ - 122℉ (0℃-50℃), <80% RH
* Storage temp, and % RH: 14℉ - 140℉ (-10℃-60℃), <70% RH
* Accessories: user's manual, carrying case, leak test bottles